Electronic Flow Switches/Sensors
3-Screen Display Digital Flow Monitor PFG300
・Can measure up to 12,000 L/min
・While checking the measured value, settings are possible.
・Current consumption: 25 mA or less
・NPN/PNP switch function
・Input range selection (for pressure/flow rate)
・Simple 3-step setting
-
2D/3D CAD
The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.
Click here for 2D/3D CAD
3-Screen Display Digital Flow Monitor PFG300
Manual
Series |
View search result |
PFG300 | |
3-Screen Display Digital Flow Monitor PFG300
DoC
Series | Applicable Flow Switch |
PFG300 | PFMB, PFMC, PF3A7□H |
Features
■Can measure up to 12,000 L/min!
■Applicable Flow Switch Variations
■Visualization of Settings
The sub screen (label) shows the item to be set.
■Easy Screen Switching
It is possible to change the settings while checking the measured value.
■NPN/PNP Switch Function
The number of stock items can be reduced.
■Analog output of 0 to 10 V is also available.
Voltage output |
1 to 5 V |
Switchable |
0 to 10 V |
Current output |
4 to 20 mA |
Fixed |
■Input Range Selection (for Pressure/Flow rate)
The displayed value to the sensor input can be set as required.
(Voltage input: 1 to 5 V/Current input: 4 to 20 mA)
Pressure switch/Flow switch can be displayed.
■Functions
●Output operation
●Simple setting mode
●Display color
●Delay time setting
●Digital filter setting
●FUNC output switching function
●ꩵSelectable analog output function
●External input function
●Forced output function
●Accumulated value hold
●Peak/Bottom value display
●Setting of security code
●Keylock function
●Reset to the default settings
●Display with zero cut-off setting
●Selection of display on sub screen
●Analog output free range function
●Error display function
●Copy function
●Power-saving mode
■Simple 3-Step Setting
When the S button is pressed and the set value (P_1) is being displayed, the set value (threshold value) can be set.
When the S button is pressed and🦩 the hysteresis (H_1) is being 🔯displayed, the hysteresis value can be set.
■Convenient Functions
Copy function
The settings of the master monitor can be copied to the slave monitors.
Secret code setting function
The key locking function keeps unauthorized persons from tampering with the settings.
Power-saving function
Power consumption is reduced by turning off the monitor.
Current consumption*1 | Reduction rate*2 |
25 mA or less | Approx. 50% reduction |
*1 During normal operation *2 In power-saving mode
External input function
The accumulated value, peak value, and bottom value can be reset remotely.
■Compact & Lightweight
Compact: Max. 6 mm shorter
Lightweight: Max. 5 g lighter (30 g / 25 g)
■Mounting
Bracket configuration allows for mounting in four orientations.
■Application Example
The flow rate of a flow switch installed in a distant place can be confirmed!