Serial Transmission System EX600
-
For Input/Output
∗The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
口碑最好的彩票平台.十大正规彩票安全平台: ▶IO-Link Devices
∗ The EX600-SPN1/SPN2 series will be discontinued in October 2023.
Please select the EX600-SPN3/SPN4 series.
口碑最好的彩票平台.十大正规彩票安全平台:Industrial IoT Cybersecurity 口碑最好的彩票平台.十大正规彩票安全平台:Glossary of Fieldbus Terms 口碑最好的彩票平台𝔉.十大正规彩票安全平台:Series🍨 Variations/Applicable Valve Series
口碑最好的彩票平台.十大正规彩票安全平台:Green Procurement (RoHS)
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX600 | IP67 | PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™ EtherNet/IP™ (IO-Link unit compatible) EtherCAT EtherCAT (IO-Link unit compatible) PROFINET PROFINET (IO-Link unit compatible) MRP (PROFINET) (Made to order) Ethernet POWERLINK (Made to order) Modbus TCP (Made to order) CC-Link IE Field (Made to order) EtherNet/IP™ (IO-Link master compatible) (Made to order) | SY3000,5000,7000 (Plug-in) JSY1000, 3000, 5000 SV1000,2000,3000 VQC1000,2000,4000,5000 S0700(IP40) |
Features
Supports digital inputs/outputs, analog inputs/outputs, and IO-Link units
IO-Link
IO-Link is a communication technology for sensors and actuators that is an international standard, IEC 61131-9.
This technology is used to send/receive device information such as manufacturer, product part number, parameters, and diagnostic data, as well as the control data including ON/OFF signals and measured values of the sensor, by connecting the IO-Link master and device in a 1:1 configuration.
IO-Link enables condition monitoring and error detection of the sensor ♛and equipment, and it can contribute t☂o the reduction of startup labor and recovery time and the realization of preventive and predictive maintenance.
IO-Link System Configuration
IO-Link Interface
The connecting part between the IO-Link unit and the device is called a “port.” Each port can be switched between “IO-Link mode” for digital communication and “standard I/O mode” for conventional contact input/output.There are two methods for power supply: one is for sensors, and the other is for actuators.
IO-Link Unit
・Can be connected with digital, analog, and IO-Link unit unitsUp to 9 IO-Link units can be connected. (36 IO-Link devices can be connected.)
Digita🐻l units, analog units, and IO-Link units can be mixed, and up to 9 units can be connected in any order.
・Supports both port class A and port class B
・The data can be accessed from via PC (setting tool).
・Diagnosis function
Diagnosis is possible from the upper level communication.
IO-Link unit (port) diagnostic information can be obtained via PLC program or PC (web browser).
Device di♏agnostic information can be obtained via PC (setting tool).
・Device parameter setting function, Automatic saving/writing
The parameter setting of devices is possible from the upper level communication.
Parameter setting is possible via PC (setting tool).
It i🦂s also possible to use output data or message data via PLC pr𝓀ogram.
EtherNet Fieldbus Functions
PROFINET (EX600-SPN3/4), EtherNet/IP™ (EX600-SEN3/4/7/8), and EtherCAT (EX600-SEC3/4) support the following functions.・Compatible topologies (Connection configuration)
・Supports the QuickConnect™ function and the Fast Start Up function
・Built-in web server function
The EX600-SEN3/4/7/8, EX600-SPN3/4, and EX600-SEC3/4 have a built-in web server function, which enables status checks,
parameter settings (EX600-SEN3/4/7/8 and EX600-SEC3/4), and forced output of the EX600 using general-purpose web browsers,
such as Microsoft Edge.
Start-up of the system and maintenance can be peဣrformed efficiently.
PROFINET Technology
System Redundancy S2As the EX600-SPN3/4 supports System Redundancy S2, it can continue communication using the backup controller when the primary controller malfunctions. This allows for the prevention of problems caused by unexpected communication interruption.
* In order to use System Redundancy S2, the PLC must be🐻 able to suppo🌊rt this function.